  Datasheet File OCR Text:
 Wire Wound Chip Inductors
LLQ1005 Series
Inductance Range: 1.0~120H
FEATURES
* High frequency surface-mounted wire-wound type small chip inductors (Size: 1.19x0.64x0.66mm Max.) * The wire is wound directory on the ceramic core at a precision pitch, realizing high-Q, self-resonant frequency characteristics with little random variation. * Wide Inductance range, and tight tolerance of 2% of the inductance value. * The top face is coated with resin, enabling the inductor to be held firmly when being mounted. * RoHS compliant. * * ( 1.19x0.64x0.66mm Max.)
Q * * * RoHS
2%
DIMENSIONS
Recommended patterns
0.21 0.58
(0.20) 0.64 Max.
1.19 Max.
0.52 0.66 Max.
0.21
0.36
(Unit: mm)
0.46
0.36
(Unit: mm)
ELECTRICAL CHARACTERISTICS
Inductance Range Inductance Tolerance 1.0~120nH G ; 2% (7.5~82nH) H ; 3% (3.3~82nH) J ; 5% (1.0~120nH) K ; 10% (1.0~120nH) S.R.F.(for reference only) 1,000~12,700MHz Rated DC current 110~1360mA Operating Temperature Range - 40C~+125C 1.0 120nH G ; 2% (7.5 82nH) H ; 3% (3.3 82nH) J ; 5% (1.0 120nH) K ; 10% (1.0 120nH) 1,000 12,700MHz 110 1360mA 40 125

EXAMPLES OF CHARACTERISTICS
LLQ1005 Inductance vs Frequency
27nH
100
Inductance (nH)
10
1
1N0
0.1 1
Q
19nH 12nH 5N6
100 90 80 70 60 50 40 30 20 10 0
LLQ1005 Q vs Frequency
12nH 19nH 27nH 5N6 1N0
10
100
1000
10000
1
10
100
1000
Frequency (MHz)
Frequency (MHz)
continued on next page
0.66
10000
Wire Wound Chip Inductors
continued from previous page
TOKO STANDARD PART NUMBERS
TYPE LLQ1005 Series (Quantity/reel; 3,000PCS)
(1) (1)
Q(1)
Q
(2)
(3)
(4)
TOKO part number LLQ1005-F1N0 LLQ1005-F1N9 LLQ1005-F2N0 LLQ1005-F2N2 LLQ1005-F2N4 LLQ1005-F2N7 LLQ1005-F3N3 LLQ1005-F3N6 LLQ1005-F3N9 LLQ1005-F4N3 LLQ1005-F4N7 LLQ1005-F5N1 LLQ1005-F5N6 LLQ1005-F6N2 LLQ1005-F6N8 LLQ1005-F7N5 LLQ1005-F8N2 LLQ1005-F8N7 LLQ1005-F9N0 LLQ1005-F9N5 LLQ1005-F10N LLQ1005-F11N LLQ1005-F12N LLQ1005-F13N LLQ1005-F15N LLQ1005-F16N LLQ1005-F18N LLQ1005-F19N LLQ1005-F20N LLQ1005-F22N LLQ1005-F23N LLQ1005-F24N LLQ1005-F27N LLQ1005-F30N LLQ1005-F33N LLQ1005-F36N LLQ1005-F39N LLQ1005-F40N LLQ1005-F43N LLQ1005-F47N LLQ1005-F51N LLQ1005-F56N LLQ1005-F68N LLQ1005-F82N LLQ1005-FR10 LLQ1005-FR12
Inductance Lo (nH) 1.0 1.9 2.0 2.2 2.4 2.7 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 8.7 9.0 9.5 10.0 11.0 12.0 13.0 15.0 16.0 18.0 19.0 20.0 22.0 23.0 24.0 27.0 30.0 33.0 36.0 39.0 40.0 43.0 47.0 51.0 56.0 68.0 82.0 100 120
Tolerance J,K J,K J,K J,K J,K J,K H,J,K H,J,K H,J,K H,J,K H,J,K H,J,K H,J,K H,J,K H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K G,H,J,K J,K J,K
Inductance Test Frequency (MHz) 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250
Q Min. 16 16 16 19 15 16 19 19 19 18 15 20 20 20 20 22 22 18 22 18 21 24 24 24 24 24 24 24 25 25 22 25 24 25 24 24 25 24 25 20 25 22 22 20 20 20
(1)
Q Test Frequency (MHz) 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250
S.R.F. (MHz) Min. 12700 11300 11100 10800 10500 10400 7000 6080 6000 6000 4770 4800 4800 4800 4800 4800 4400 4100 4160 4000 3900 3680 3600 3450 3280 3100 3100 3040 3000 2800 2720 2700 2480 2350 2350 2320 2100 2240 2030 2100 1750 1760 1620 2000 1100 1000
(2)
RDC () Max. 0.045 0.070 0.070 0.070 0.068 0.120 0.066 0.066 0.066 0.091 0.130 0.083 0.083 0.083 0.083 0.10 0.10 0.20 0.10 0.20 0.20 0.12 0.12 0.21 0.17 0.22 0.23 0.20 0.25 0.30 0.30 0.30 0.30 0.30 0.30 0.44 0.55 0.44 0.81 0.83 0.82 0.97 1.12 2.24 2.52 2.66
(3)
Rated DC (4) Current (mA) Max. 1360 1040 1040 960 790 640 840 840 840 700 640 800 760 760 680 680 680 480 680 480 480 640 640 440 560 560 420 480 420 400 400 400 400 400 400 320 200 320 100 150 100 100 100 100 120 100
Add the tolerance of inductance to within the
of the part Number as follows: G=2%, H=3%, J=5%, K=10% G=2%, H=3%, J=5%, K=10%
(1) technologies) (2) (Agilent technologies) (3) technologies) (4) 20 20 HP3442A (Agilent HP8720ES Q LCR HP4287A (Agilent
(1) Inductance and Q is measured with a RF LCR meter HP4287A (Agilent technologies) or equivalent. (2) Self resonant frequency is measured with a network analyzer HP8720ES (Agilent technologies) or equivalent. (3) DC resistance is measured with a micro ohm meter HP3442A (Agilent technologies) or equivalent. (4) Rated DC current is coil temperature to rise by 20 . (Reference ambient temperature 20 )